Not known Details About Australian Standard 4586
Not known Details About Australian Standard 4586
Blog Article
ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6
When it comes to guaranteeing security in business, commercial, and residential spaces, slip resistance testing is a crucial element. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist services and homeowner alleviate threats and abide by security requirements.
With modern devices such as the pendulum slip test maker and moisture meter for concrete, we supply precise and independent slip testing services throughout Australia. Our know-how covers ASTM F2170 compliance, R Ranking evaluations, P Ranking tiles, and more, ensuring your floors fulfill the greatest security standards.
Why Slip Resistance Testing is Vital
Slips and falls are amongst the leading causes of work environment and public injuries. Proper slip testing helps identify harmful surface areas before mishaps take place. Whether you require damp pendulum test assessments or pendulum test for slip resistance, ATTAR delivers precise outcomes to boost security.
Key Services Offered by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Rating and P Ranking tiles evaluations.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test using advanced moisture meter for concrete.
- ASTM F2170 compliant evaluations.
- Concrete slab moisture testing to prevent floor covering failures.
3. Luminance Contrast Testing
- Guarantees visibility for aesthetically impaired people.
- Complies with Australian ease of access standards.
4. On-Site & Lab Testing
- Slip test device for accurate on-site evaluations.
- Wet pendulum test for damp surface slip resistance.
Understanding Slip Resistance Rankings: R Score vs. P Rating
When conducting slip resistance testing, 2 essential classifications are utilized:.
- R Score (Ramp Test - DIN 51130)
Measures slip resistance under lubricated conditions, frequently used in Europe.
- P Rating (Pendulum Test - AS 4586)
Examines dynamic friction utilizing a pendulum test slip resistance device, widely embraced in Australia.
ATTAR offers independent slip testing to determine whether your floor covering meets the needed pendulum score tiles standards.
The Significance of Concrete Moisture Testing
Excess moisture in concrete slabs can lead to floor covering failures, mold growth, and adhesive destruction. Our concrete moisture testing services consist of:.
> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to ensure optimum conditions for floor installations.
By identifying moisture problems early, we assist prevent pricey repairs and make sure long-lasting floor covering performance.
Luminance Contrast for Availability Compliance
Proper luminance contrast is vital for visually impaired people to browse spaces securely. ATTAR evaluates:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.
Our assessments guarantee compliance with Australian Special needs Standards (AS 1428.1).
Why Select ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where relevant).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Reputable Reporting.
For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Common Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping center, restaurants, and offices need safe flooring to prevent customer and worker injuries. Our pendulum slip test ensures compliance with security regulations.
2. Industrial & Storage Facility Facilities
High-traffic industrial environments require durable, slip-resistant floor covering. ATTAR's slip testing services help keep workplace security.
3. Healthcare & Aged Care Facilities
Health centers and nursing homes should lessen slip risks. Our luminance contrast and slip resistance testing ensure safe mobility for clients and personnel.
4. Public Infrastructure
Footpaths, train stations, and government structures need independent slip testing to fulfill accessibility and safety standards.
How ATTAR Carries Out Slip Resistance Testing
Action 1: Surface Area Evaluation
We evaluate flooring materials and conditions (dry, damp, or polluted).
Action 2: Pendulum Slip Test (AS 4663)
Utilizing a slip test maker, we measure the dynamic coefficient of friction (DCOF).
Step 3: Wet Pendulum Test
Mimics slippery conditions to evaluate real-world slip dangers.
Step 4: Reporting & Compliance Accreditation
In-depth reports with R Ranking or P Ranking tiles categories.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance method involves a swinging arm with a rubber slider that mimics a foot's movement. The test measures:.
- Slip Potential Value (SPV).
- Pendulum rating tiles classification (P0 to P5).
Higher ratings (P4/P5) indicate better slip resistance.
Moisture Testing for Concrete Floors: Preventing Failures
Moisture-related flooring failures can be costly. ATTAR's concrete slab moisture testing includes:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot checks.
- Slab moisture test data analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's trusted provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast read more evaluations. With cutting-edge technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and certified testing services.
Guarantee your residential or commercial property satisfies safety standards-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By choosing ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security services. Let us help you create safer, certified, and moisture-resistant environments. Report this page